S Type LCS-S3 -0.2kN-100kN Load Cell-Tension and Pressure
Introduction
1. High accuracy, reliability, and stability
2. Tension or compression
3. Compatible, installing easily, and good interchangeability
4. Applying to crane scale, batcher scale, packing scale, electro-mechanic scale and so on
5. Optional measurement range: 0.2kN- 100kN (approximate 20kg-10t)
Technical Data
Description | |
Material | Alloy Steel or Stainless Steel |
Rated Load(kN) | 0.2/0.3/1/2/3/5/10/20/30/50/75/100 |
Performance | |
Overall Precision | 0.02(linearity+ hysteresis+ repeatability) |
Sensitivity | 2.0mV/V (0-75kN);1.8mV/V (100kN) |
Excitation Voltage | 5-12V DC recommend 10V DC |
Creep (in 30min) | ±0.03%F.S/30min |
Zero Balance | ±1%F.S |
Input Resistance | 400±20Ω |
Output Resistance | 352±3Ω |
Insulation Resistance | ≥5000MΩ |
Working Environment | |
Safety Overload | 150%F.S |
Ultimate Overload | 200%F.S |
Operation Temperature Range | -30-+70℃ |
Zero Drift | ±0.02%F.S/10ºC |
Output Drift | ±0.02%F.S/10ºC |
Protection Class | IP65 |
Dimension
Rated Load(kN) | Dimension (Unit: mm, Error: ±1mm) | ||||
A | B | C | R | D | |
0.2-1.5 | 64 | 70 | 12 | 74 | M8×1.25 |
2-5 | 64 | 70 | 20 | 74 | M12×1.75 |
7-10 | 64 | 70 | 25 | 74 | M12×1.75 |
12-50 | 90 | 90 | 32 | 94 | M20×2 |
75 | 90 | 90 | 40 | 94 | M24×2 |
100 | 110 | 110 | 50 | 94 | M30×2 |
安装及接线图
Write your message here and send it to us